Corporate Office VRV
Daikin VRV IV serving 5-storey office; 32% energy saving versus replaced split AC; commissioned in 60 days.
Eight verticals, one engineering team — from the first survey to the last commissioning signature.
Condensing units, ZEAS and Conveni-Pack sized, supplied and commissioned by our own team.
Explore Daikin rangeBankable DPRs and scheme documentation, prepared by the engineers who design the project.
Tell us the crop, capacity and state. We map every scheme you can stack, before you spend on a DPR.
Check my eligibilityInstrument-grade calculators built on the same cost norms our engineers quote from.
Calculators give the range. Our engineers turn it into a site-specific BOQ with subsidy mapped.
Request an estimateGuides, cost breakdowns and state-by-state playbooks written by project engineers.
Design norms, cost sheets, DPR samples and scheme notes — organised the way a project is built.
Open the resource library
Daikin commercial air conditioning systems — VRV, VRF, ducted splits, chillers and precision AC — power modern offices, hotels, hospitals, malls and process facilities across India. AgriMotion supplies and installs genuine Daikin commercial AC systems with engineering design, MEP integration, BMS interfacing and lifecycle service. From a 5 TR ducted split for a clinic to a 500 TR chiller plant for a corporate campus, we deliver Daikin AC projects with single-vendor accountability and authorized service access.
Daikin VRV (Variable Refrigerant Volume) is a multi-split air conditioning system where one outdoor unit serves multiple indoor units (up to 64) of mixed type and capacity via a refrigerant network. VRV uses inverter compressor modulation to match exact cooling demand, delivering 30–40% energy savings versus conventional split AC.
Daikin Commercial AC from AgriMotion Engineering is built for the following types of operators across India:
Daikin VRV IV / V delivers 30–40% energy saving versus conventional split AC through inverter compressor modulation and refrigerant volume control.
One outdoor unit serves 4–64 indoor units of mixed type and capacity — cassette, ducted, hi-wall, floor-standing.
VRV supports refrigerant piping runs up to 165 m total — allowing rooftop outdoor units even in tall buildings.
3-pipe VRV simultaneously cools and heats — recovers heat from cooling zones to warm other zones. Ideal for hotels and hospitals.
Daikin BACnet / Modbus gateway integrates with Honeywell, Schneider, Siemens, Johnson Controls BMS for centralised control.
Indoor units operate at 28–35 dB — quieter than ambient office noise. Ideal for boardrooms, libraries and hospital wards.
Brushless DC fan motors, factory-sealed scroll compressors and self-cleaning indoor units reduce service interventions.
Daikin authorized service in 100+ cities with online service request tracking.
Daikin commercial AC delivers the lowest total cost of ownership over 10–15 year life — capex premium recovered in 3–4 years from energy savings.
Every stage closes with a document you keep — nothing is manufactured before the design is locked.
We capture commodity, capacity, location, civil readiness and budget envelope on a 30-minute consultation.
Day 0–2A bankable Detailed Project Report with BOQ, drawings, subsidy mapping and 3-year ROI is delivered.
Day 3–7Senior engineer visits the site to validate civil, power, water, drainage and access logistics.
Week 2GA drawings, panel layout, refrigeration P&ID and electricals are frozen; advance PO is raised.
Week 3PUF panels, refrigeration skids, structural steel and BOP are factory-built and despatched in QC-cleared batches.
Week 4–10Site erection, refrigerant charging, electrical termination, trial run, operator training and handover.
Week 8–12Not on the list? Send the drawing or a site photo — we engineer to the requirement, not the catalogue.
Ask an engineerA sample of projects delivered by AgriMotion across India.
Daikin VRV IV serving 5-storey office; 32% energy saving versus replaced split AC; commissioned in 60 days.
Two Daikin centrifugal chillers in N+1 redundancy; BMS-integrated with cooling tower and AHU loop.
Daikin 3-pipe VRV with simultaneous heating/cooling for wards, OT and reception zones.

Still unsure? Speak to an engineer — not a sales desk.
Daikin VRV (Variable Refrigerant Volume) is a multi-split air conditioning system where one outdoor unit serves multiple indoor units (up to 64) of mixed type and capacity via a refrigerant network. VRV uses inverter compressor modulation to match exact cooling demand, delivering 30–40% energy savings versus conventional split AC.
VRV is Daikin's trademark; VRF (Variable Refrigerant Flow) is the generic term. Functionally they are the same technology. Daikin invented VRV in 1982 and remains the global leader. Other brands market equivalent systems as VRF.
VRV suits commercial buildings up to ~500 TR with modular zoning needs (offices, hotels, hospitals). Central chillers suit larger campuses (500+ TR) and industrial process cooling. VRV has lower install cost, faster commissioning, no chilled water piping; chillers have lower per-TR opex at very large scale.
Properly maintained Daikin commercial AC systems deliver 12–18 years of service life. Compressors carry 3-year warranty with field-proven 10–15 year life. AMC and predictive maintenance significantly extend service life.
Yes. Daikin BACnet IP / Modbus TCP gateway integrates seamlessly with major BMS platforms (Honeywell EBI, Schneider EcoStruxure, Siemens Desigo, Johnson Metasys). We design and commission the integration end-to-end.
Standard ducted splits and Skyair units: 2–3 weeks. VRV outdoor and indoor units: 4–6 weeks. Centrifugal chillers: 10–14 weeks. Lead times are project-dependent — we confirm at PO stage.
Yes. AgriMotion offers comprehensive and non-comprehensive AMC plans for Daikin commercial AC, including quarterly preventive maintenance, refrigerant top-up, control board diagnostics and breakdown response. AMC typically priced at 4–7% of equipment value.
For server rooms, we recommend Daikin precision AC (PCAC) — close-control units with tight ±1°C and ±5% RH tolerance, downflow configuration, hot-aisle/cold-aisle compatible. Sizes from 5 to 60 TR with N+1 redundancy.
A crop, a capacity and a location are enough to begin. Share drawings or site photos on WhatsApp if you have them.